User's Manual

TRACER 2xT1 Users Manual
61280003L2-1B
Section 1 TRACER Description
9Preliminary
Three SMA connectors, located on the RFC module, provide RF and IF connection points. A test point is
provided for monitoring the received signal strength indicator (RSSI). The voltage (relative to the GND
test point) present on this test point represents the level of the received signal. This signal is used to align
the antenna when installing the system and to verify the link is performing as designed. Another test
point is provided to monitor the transmitter output power during system configuration. The only
connections that must be made in the field are a coax connection between the baseband processor and the
RFC and a coax connection between the RFC and the antenna. These connections require male, type N
coax connectors.
The IF connector provides the connection between the baseband processor and the rackmounted or
mastmounted RFC. (An 8-inch IF cable [ADTRAN part # 3125RF027@A] is provided for rackmount
systems). The TO ANTENNA connection provides the connection between the RFC and the antenna. A
block diagram of the RFC functions is show in Figure 1-9.
The RFC module is enclosed in either a 19-inch EIA rackmount housing, or a weather-tight enclosure
suitable for mastmounting near the antenna for enhanced system performance. The RFC mastmount and
rackmount housings are illustrated in Figures 1-10 and 1-11.
Figure 1-8. RFC Module
R
X
T
X
I
F
R
S
S
I
G
N
D
T
X
-P
W
R
Figure 1-9. RFC Function Block Diagram
SAW
333
2321
2281
AGC
Splitter
Splitter
AGC
PA
LPF
RF2
IF
2018 5344
or
2058 5424
5607
or
5687
Tx
Rx