User's Manual

TRACER 2xT1 Users Manual
61280003L2-1B
Section 3 Operation
35
Preliminary
Remote Current System Status
Elapsed Time 00:21:13
----- ADTRAN Technical Support - 256/963-8716 -----
| C | / ->>---->>---->>--->[RF UP]>---->>---->>---->>- \ | C |
T1 ===| S |#(- -)#| S |=== T1
| U | \ -<<----<<----<<----[RF UP]<----<<----<<----<<- / | U |
----- -----
Local Tracer Remote Tracer
Freq Plan B Freq Plan A
Tx Pwr Rx Pwr Tx Pwr Rx Pwr
Max [ ] [X] Nominal Max [ ] [X] Nominal
[ ] [X] [ ] [X]
[ ] [X] Site: Adtran [ ] [X]
[ ] [X] [ ] [X]
[X] [X] RFC Link Up: Yes [X] [X]
[X] [X] Code Sync: Yes [X] [X]
[X] [X] Carrier Sync: Yes [X] [X]
[X] [X] E1 Link Sync: Yes [X] [X]
[X] [X] Chipping Code: 9 [X] [X]
[X] [X] [X] [X]
Min [X] [X] Min Min [X] [X] Min
==============================================================================
Press 'm' - Main menu, '~' to exit remote mode:
Figure 3-13. Remote Current System Status
Site ID allows a string of up to 32 characters to be entered as a site identifier.
Enable T1 B disables Alarm and LEDs related to T1-B, but will pass T1 data.
TBOS # changes the TBOS Equipment ID.
Enable Modem Control enables modem control leads on RS 232 port. See Modem Connection under
Operation Section.
Hangup Modem lowers the DSR signal, which becomes DTR after passing through the null modem
adapter. When modem is configured to disconnect on loss of DTR, the connection will drop.
REMOTE ACCESS
This allows access to the remote radio via the RF communications link. When accessed, the user will be
able to identify remote mode by each screen titled "Remote." The remote menus are accessed via a 2400
bps link causing screen refresh to be slower than local mode. All pages are displayed as if the user were
connected to the VT-100 terminal at the remote end of the link. Every screen that can be accessed at the
local radio can be accessed at the remote radio via this option.