RS-232 Connection (Terminal Use)
The RS-232 connector provides a female DB-25 terminal connection (wired as a DCE interface), which is
used for terminal access to the TRACER 4106/4206 system. The RS-232 port provides the following
functions:
Accepts EIA-232 input from a PC or terminal for controlling the TRACER 4106/4206 system
Operates at 9600 bps
Tab le 6 on page 28 shows the pinout. Wiring diagrams for connecting to the RS-232 connector (for
various applications) are provided following the pinout.
Connector type
DB-25
Table 6. RS-232 Connection Pinout
PIN NAME DESCRIPTION
1, 7 GND GROUND
2 TX TRANSMIT
3 RX RECEIVE
4 RTS REQUEST TO SEND
5 CTS CLEAR TO SEND
6 DSR DATA SET READY (MODEM CONTROL ONLY)
8 CD CARRIER DETECT
9-19 UNUSED
20 DTR DATA TERMINAL READY (MODEM CONTROL ONLY)
21 UNUSED
22 RI RING INDICATOR
23-25 UNUSED
Table 7. TRACER 4106/4206 (DCE) to Terminal (DTE) Diagram (DB-25)
PIN NAME PIN NAME
2 TX 2 TX
3 RX 3 RX
4 RTS 4 RTS
5 CTS 5 CTS
6 DSR 6 DSR
7 GND 7 GND