User Manual
Table Of Contents
- System Description
- Microwave Path Engineering Basics
- Engineering Guidelines
- Network Turnup Procedure
- User Interface Guide
- 1. Navigating the Terminal Menu
- 2. Terminal Menu and System Control
- 3. Menu Descriptions
- >TRACER System Status
- >Main Menu
- >TRACER System Configuration
- >TRACER Link Performance History
- >T1A Status/Configuration/Loopback
- >T1A Performance History
- >T1B Status/Configuration/Loopback
- >T1B Performance History
- >T1C Status/Configuration/Loopback
- >T1C Performance History
- >T1D Status/Configuration/Loopback
- >T1D Performance History
- Troubleshooting Guide
TRACER 4206 System Manual Section 5, User Interface Guide
612804206L1-1B © 2002 ADTRAN, Inc. 57
>T1C STATUS/CONFIGURATION/LOOPBACK > LINE CODE
Sets the line coding for the T1C link. The TRACER 4106/4206 supports B8ZS and AMI line coding.
>T1C STATUS/CONFIGURATION/LOOPBACK > LOOP/NORMAL STATE
Controls the loop status of the T1C link. Activates/deactivates loopback conditions for testing purposes.
>T1C STATUS/CONFIGURATION/LOOPBACK > LOOP/NORMAL STATE > NORMAL
The T1C link is in normal data transport mode - there are no active loopbacks.
>T1C STATUS/CONFIGURATION/LOOPBACK > LOOP/NORMAL STATE > LINK
Activates a loopback at the TRACER 4106/4206 T1C framer towards the wireless link (see Figure 17).
Use the
L
INK
loopback to test data path integrity from one unit across the wireless link.
Figure 17. T1C Link Loopback
>T1C STATUS/CONFIGURATION/LOOPBACK > LOOP/NORMAL STATE > LINE
Activates a loopback at the TRACER 4106/4206 T1C framer towards the wireless link (see Figure 18).
Use the
L
INE
loopback to test data path integrity from the TRACER 4106/4206 unit to the T1 equipment.
Figure 18. T1C Line Loopback