Section 5, User Interface Guide TRACER 4205 System Manual
46 © 2002 ADTRAN, Inc. 612804205L1-1A
>DS3 STATUS/CONFIGURATION/LOOPBACK
Figure 6 shows the DS3 Status/Configuration/Loopback menu page. Real-time graphical representation for
the DS3 link (using data from both the local and remote TRACER 4205 units) is displayed on this page.
DS3 operational configuration parameters and testing functions are configured from this menu.
Figure 6. DS3 Status/Configuration/Loopback
>DS3 STATUS/CONFIGURATION/LOOPBACK > DS3 INTERFACE ALARMS
Displays any active alarms on the DS3 link (reported from both the local and remote TRACER 4205
units). These alarms include Red, Blue, Yellow, AIS, and bipolar violations (BPV). See Section 6,
Troubleshooting Guide, for more information on these alarms.
Press <3> from any menu in the TRACER 4205 VT100 menu structure to access the
DS3 Status/Configuration/Loopback menu page.
Table 1. DS3 Interface Alarms
BPV Activates when the incoming DS3 stream presents bipolar violations (BPVs). BPVs are
received when two consecutive “one” bits are the same polarity.
AIS An AIS signal is a properly aligned and framed alternating one-zero pattern. The TRACER
4205 will transmit a blue alarm (RMT) to the remote equipment when an incoming alarm is
received from a connected DS3 device. The remote equipment should transmit the AIS
yellow alarm which will be passed by the TRACER 4205 to the connected DS3 device.
RMT Activates when an incoming remote alarm is received (from the DS3 equipment) in the
DS3 EOC channel (bits X1 and X2 are both set to zero).