Service manual

FORM NO. 56043098 - Convertamatic
24C, 24D, 26C, 26D, 28C, 28D - 23
SCRUB SYSTEM
SCRUB BRUSH MOTOR/GEARBOX REMOVAL (DISC)
1 Follow the steps in the Scrub Brush Deck Removal (Disc) section.
2 Turn the brush deck on its back.
3 Remove the scrub brushes from the brush holders. If removing both motor/gearboxes mark the location of the holders and motors to the brush deck for proper
re-assembly.
4 See Figure 3. Remove the (3) (E) Hex Screws from the exible coupler that attaches the brush holder to the drive Hub (F) of the Motor/Gearbox Assembly
you want to remove.
5 Remove the (1) Hex Screw (G) that secures the Hub (F) to the output shaft on the defective motor/gearbox. Then pull the hub from the shaft and save the
key.
6 Remove the (4) (H) Screws and separate the defective Motor/Gearbox Assembly (I) from the scrub deck.
7 Re-assemble in reverse order and test for proper operation. Note: Apply a small amount of grease or a product called “Never Seize” to the gearbox output shaft
when reinstalling the Drive Hubs (F).
FIGURE 3