RECOVERY SYSTEM
VACUUM MOTOR REMOVAL
1 Drain the recovery tank using the drain hose.
2 Turn the key off and disconnect the battery pack
3 Swing open the recovery tank and disconnect the vacuum motor harness connector.
4 See Figure 5. Remove the vacuum motor Shroud Cover (A) secured to the bottom of the recovery tank (qty 4 screws).
5 Loosen the exhaust hose clamp and remove Hose (B) from the vacuum motor discharge tube and completely remove the Vacuum Motor (C) from its mount
cavity. NOTE: Take care not to loose the 3 (D) Vibration Mounts.
6 Inspect the condition of the Vacuum Motor Gasket (E) inside the vacuum motor mount cavity.
7 Make service repairs to the Vacuum Motor and re-install by following steps in reverse order.