Service manual

FORM NO. 56043098 - Convertamatic
24C, 24D, 26C, 26D, 28C, 28D - 67
ELECTRICAL SYSTEM
MAIN CONTROL PROGRAMMING OPTIONS (CONTINUED)
Heavy Scrub Setting Adjustment:
FACTORY DEFAULT: SCRUB PRESSURE =2, SOLUTION = TWO BARS, CHEMICAL = 0 (IF AVAILABLE).
The heavy scrub pressure, solution rate and chemical rate can be programmed depending on its application where high solution rate is need with light scrub pressure
or low solution rate with heavy scrub pressure. To change scrub pressure setting, solution rate setting and chemical setting, perform the following steps:
1 Turn the main power key switch to the off position.
2 Press and hold the scrub on and the chemical switch.
3 While holding both switches, turn the main power key switch to the on position.
4 Continue to hold the both switches until the wand indicator and heavy scrub indicator turn green.
5 Release both switches. The display will now show disc icon with current scrub pressure setting. Scrub off indicator will turn red and heavy scrub indicator will
turn yellow.
6 Pressing scrub on switch will now select new scrub pressure. Pressing scrub off switch will save the new setting and move to solution rate setting.
7 The display will now show solution icon with gauge. Heavy scrub indicator will now turn green and solution indicator will turn yellow. Pressing solution switch
will now select new solution rate. Pressing scrub off switch will save the new setting and move to chemical setting (If available).
8 The display will now show chemical bottle with current chemical setting. Solution indicator will turn green and chemical indicator will turn green. Pressing
chemical switch will now select new chemical setting. Pressing scrub off switch will save the new setting and display key switch icon on display.
9 Turn the main power key switch to the off position.
10 The new settings will be saved and will remain in effect until it is changed again.
Extreme Scrub Setting Adjustment:
FACTORY DEFAULT: SCRUB PRESSURE =3, SOLUTION = THREE BARS, CHEMICAL = 0 (IF AVAILABLE).
The extreme scrub pressure, solution rate and chemical rate can be programmed depending on its application where high solution rate is need with extreme scrub
pressure or low solution rate with heavy scrub pressure. To change scrub pressure setting, solution rate setting and chemical setting, perform the following steps:
1 Turn the main power key switch to the off position.
2 Press and hold the scrub on and the recycle switch.
3 While holding both switches, turn the main power key switch to the on position.
4 Continue to hold the both switches until the recycle indicator and light and heavy scrub indicators turn green.
5 Release both switches. The display will now show disc icon with current scrub pressure setting. Scrub off indicator will turn red and light and heavy scrub
indicator will turn yellow.
6 Pressing scrub on switch will now select new scrub pressure. Pressing scrub off switch will save the new setting and move to solution rate setting.
7 The display will now show solution icon with gauge. Light and heavy scrub indicators will now turn green and solution indicator will turn yellow. Pressing
solution switch will now select new solution rate. Pressing scrub off switch will save the new setting and move to chemical setting (If available).
8 The display will now show chemical bottle with current chemical setting. Solution indicator will turn green and chemical indicator will turn green. Pressing
chemical switch will now select new chemical setting. Pressing scrub off switch will save the new setting and display key switch icon on display.
9 Turn the main power key switch to the off position.
10 The new settings will be saved and will remain in effect until it is changed again.