DETERGENT (AXP™ / ECO+Solution™) SYSTEM PREPARATION AND USE
Fill the detergent cartridge with a maximum of 1.25 gallons (4.73 Liters) of detergent. SERVICE NOTE: Remove the detergent cartridge from the detergent box
prior to fi lling to avoid spilling detergent on the machine.
It is recommended that a separate cartridge be used for each detergent you plan to use. The detergent cartridges have a white decal on them so you can write
the detergent name on each cartridge to avoid mixing them up. The detergent cartridge has a Magnetic Slider (AA) on one end that needs to be set to the proper
dilution ratio according to the dilution instructions on the manufacturer’s bottle. Slide the Magnet Slider (AA) to the appropriate location on Detergent Dilution
Ratio Decal (BB). The system should be purged of previous detergent when switching to a different detergent. SERVICE NOTE: Move machine over fl oor drain
before purging because a small amount of detergent will be dispensed in the process.
To Purge When Changing Chemicals:
1 Disconnect and remove the detergent cartridge.
2 Turn the Key Switch (A) ON and press the Detergent Switch (F) and the Solution Switch (B) down for at least 3 seconds. NOTE: Once activated the purge
process takes 10 seconds. See illustration on next page for Detergent System indicators. Normally one purge cycle is adequate to purge the system.
To Purge Weekly:
1 Disconnect and remove the detergent cartridge. Install and connect a Cartridge fi lled with clean water
2 Turn the Key Switch (A) ON and press the Detergent Switch (F) and the Solution Switch (B) down for at least 3 seconds. NOTE: Once activated the purge
process takes 10 seconds. See illustration on next page for Detergent System indicators. Normally one purge cycle is adequate to purge the system.
When the Detergent Cartridge is almost empty a Display Panel (D) indicator will come on. This “Low Detergent” indicator will remain on until you reset the system.
Once this indicator comes on you should be able to simply pour an entire gallon bottle of detergent into the Cartridge to refi ll without worrying about measuring.
NOTE: Only reset the system when the cartridge is full. When switching cartridges, the “Low Detergent” indicator is only accurate if the replacement cartridge is
at the same level as the cartridge being replaced.
To Reset:
1 Turn the Key Switch (A) ON and hold the Detergent Switch (F) down for 3 seconds. See the illustration to the right for Detergent System indicators.