User's Manual
32
Face Recognition Scanner user's manual Face Recognition Scanner user's manual
Biometric products cannot be 100% suitable for any anti-counterfeiting environment.
High security level places, please use combination authentication.
Do not touch the temperature probe with your ngers or blow the probe.
Please make sure no hair, sweat, or hat cover your forehead before measuring
temperature.
If the forehead is cold, wait for the forehead to become warm before taking the
temperature measurement. Such as: after washing the face, after applying ice, after
entering the room from the outside in winter.
1. Product Appearance
Color Camera
Temperature Probe
White Fill Light
Infrared Fill Light
Infrared Camera
LCD Screen
The Face Recognition Scanner supports 3 usage modes, and is equipped with dierent
platform software for more powerful functions.
1. Access Control & Attendance for Company | Equipped with Attendance & Access
Control Management Platform Software for Company.
2. Access Control & Attendance for School | Equipped with Attendance & Access
Control Management Platform for School.
3. Quick Screening | Used for quick temperature screening.
Notice:
To ensure the normal operation of the temperature measurement module, the
device needs to be warmed up for more than 2 hours after it is powered on.
During installation and use, all electrical safety regulations of the country and the
region of use must be strictly observed.
When wiring, disassembling and other operations, please be sure to disconnect the
power supply, do not operate with electricity.
If the device emits smoke, produces unusual odors, or makes noises, immediately
turn o the power and unplug it, and contact the dealer or service center in time.
If the equipment is not working properly, please contact customer service, do
not disassemble or modify the equipment in any way. (The company does not
assume any responsibility for problems caused by unauthorized modification or
maintenance)
Do not drop objects on the device or vibrate the device vigorously to keep the device
away from magnetic interference.
Avoid installing the device where the surface vibrates or is vulnerable to shock.
Avoid installing the device at the air outlet of the air conditioner or in a place with
large airow uctuations.
Try to ensure that the equipment is installed vertically.
Please do not use the device in high temperature, low temperature or high humidity
environment.
Please do not aim the lens of the device at strong light objects such as the sun,
incandescent lamp, etc., otherwise it will cause lens damage.
Avoid placing the device in direct sunlight, poorly ventilated locations, or heat source
accessories such as heaters or heaters.