Offset  Field  Size  Value  Description 
0  bMessageType  1  65h   
1  dwLength 
<LSB .. MSB> 
4  00000000h  Message-specific data length 
5  bSlot  1  00h,01h  00h forPICC interface, 01h for ICC 
6  bSeq  1  00-FFh  Sequence number for command 
7  abRFU  3    Reserved for Future Use 
8.5 HOST_to_RDR_SetParameters 
This command is used to change the parameters for contact interface to implement PPS. 
Command Frame Format 
STX 
(0x02) 
Bulk-OUT Header 
(HOST_to_RDR_XfrBlock) 
Parameters  Checksum
ETX 
(0x03) 
1 Byte  10 Bytes  5 or 7 bytes  1 Byte  1 Byte 
HOST_to_RDR_SetParameters Format 
Offset  Field  Size  Value  Description 
0  bMessageType  1  61h   
1  dwLength 
<LSB .. MSB> 
4  00000005h, 
00000007h 
Message-specific data length 
5  bSlot  1  00h,01h  00h forPICC interface, 01h for ICC 
6  bSeq  1  00-FFh  00h for protocol T=0, 01h for T=1. 
7  bProtocolNum  1  00h,01h  Used to extend the Block Waiting 
Timeout. 
8  abRFU  2    Reserved for Future Use 
10  abProtocolDataStructure
Byte 
array 
  Protocol Data Structure 
Remarks: 
For protocol T = 0, dwLength = 00000005h; for protocol T = 1, dwLength = 00000007h. More 
detail about the abProtocolDataStructure field, please refer to CCID specification. 
8.6 HOST_to_RDR_Escape 
This command is used to peripherals control such as LED & Buzzer control, Get firmware 
Version, set the serial communication mode and so on. 
Command Frame Format 
STX 
(0x02) 
Bulk-OUT Header 
(HOST_to_RDR_XfrBlock) 
Commands  Checksum
ETX 
(0x03) 
1 Byte  10 Bytes  M bytes  1 Byte  1 Byte 
HOST_to_RDR_Escape Format 
Offset  Field  Size  Value  Description 
0  bMessageType  1  6Bh   
1  dwLength 
<LSB .. MSB> 
4  M  Message-specific data length 