PICC APDU COMMANDS FOR GENERAL PURPOSES 
1. Get Data 
The “Get Data command” will return the serial number or ATS of the “connected PICC”. 
Table 1.1-1a: Get UID APDU Format (5 Bytes) 
Command 
Class  INS  P1  P2  Le 
Get Data  FF  CA  00 
01 
00  00 
(Max 
Length) 
Table 2.1-1b: Get UID Response Format (UID + 2 Bytes) if P1 = 0x00 
Response 
Data Out 
Result 
UID 
(LSB) 
    UID 
(MSB) 
SW1  SW2 
Table 2.1-1c: Get ATS of a ISO 14443 A card (ATS + 2 Bytes) if P1 = 0x01 
Response 
Data Out 
Result 
ATS  SW1  SW2 
Table 2.1-1d: Response Codes 
Results 
SW1  SW2  Meaning 
Success  90  00  The operation is completed successfully. 
Warning  62  82  End of UID/ATS reached before Le bytes 
(Le is greater than UID Length). 
Error  6C  XX  Wrong length (wrong number Le: ‘XX’ 
encodes the exact number) if Le is less 
than the available UID length. 
Error  63  00  The operation is failed. 
Error  6A  81  Function not supported 
Examples: 
// To get the serial number of the “connected PICC” 
UINT8 GET_UID[5]={0xFF, 0xCA, 0x00, 0x00, 0x00}; 
// To get the ATS of the “connected ISO 14443-4 A PICC” 
UINT8 GET_ATS[5]={0xFF, 0xCA, 0x01, 0x00, 0x00}; 