Proper Single Gang Installation
Using ZDW103’s standard full heat-sink (all tabs), the connected incandescent lamp load shall not exceed 500W.
If a tab is removed from one side of the ZDW103 unit, the connected incandescent lamp load must not exceed 400W.
If both tabs are removed from the ZDW103 unit, the connected incandescent lamp load must not exceed 300W.
Proper Dual Gang Installation
The connected incandescent lamp load must not exceed 400W for each of the two ZDW103 units.
Proper Triple Gang Installation
The connected incandescent lamp load must not exceed 300W for each of the three ZDW103 units.
Air Gap Switch
The ZDW103 has an air gap switch on the face (lower left), that when pulled out, completely removes the power
available to the load (simply turning the dimmer off does not). This enables the lamps that are controlled by the device
to be changed with minimal danger of electrical shock. The air gap switch must be pushed all the way back in for
the dimmer to operate the lamps again.
INCLUDING ZDW103 TO THE NETWORK
STEP 1.. Prepare the Controller to include a unit to the network by adding it to a group (method of adding a node
to the network). Refer to controller instructions.
STEP 2. The ZDW103 must be in its permanently installed location. Tap either the top or bottom of the
ZDW103 switch once.
STEP 3. You should see an indication on your Controller that the “DEVICE WAS INCLUDED” in the network.
NOTE: If you have trouble adding the ZDW103 to a group it may be that the Home ID and Node ID were
not cleared from it after testing. You must first “RESET UNIT” with your controller to remove it from the net-
work. If using the ZTH100 select “SETUP” and scroll to “RESET UNIT”
Although adding it to a group includes it in the network, removing it from a group does not remove it from the
network. If removed from a group, it functions only as a repeater.
BASIC OPERATION
Local Control
The top or bottom of the ZDW103 switch can be used to carry out inclusion (add to a group), association, exclusion
(remove from group) or reset (remove from network).
Pushing the top or bottom of the switch, the ZDW103 allows the user to do the following:
Turn ON, OFF, DIM or BRIGHTEN the load attached.
Include or exclude the module from the Z-Wave network.
Configure to Control Shades or Window Coverings via Z-Wave network.
Control other Z-Wave enabled devices.
Also, when a controller prompts you to “Send Node ID” or to “Press Button on Unit”, quickly tap the top or bottom
of the switch once to satisfy those instructions.
• Tapping top of the switch turns the load attached ON.
• Tapping bottom of the switch turns the load attached OFF.
Pressing and holding the top of the switch will brighten the load attached, and pressing and holding the bottom
of the switch will dim the load. When OFF, pressing and holding the bottom of the switch will cause the load
will go to the minimum dim level.
Note: Upon restoration of power after a power loss, the ZDW103 returns to previous known state.
LED indication
The LED on the ZDW103 will turn on when the load attached is ON. However, the LED can be user configured to
turn ON when the load attached is OFF, if so desired, to act as a night light.