User guide
106
APPENDIX G: Aerosance FADEC Interface
The Engine Monitor can be configured to display engine data from an
Aerosance SBC FADEC control unit with a RS-232 data connection connected
to EFIS Serial Port #3
Wiring Connections:
Aerosance SBC Function EFIS Main Cable
TXD Serial Port #3 RXD Pin 5
GND Serial Serial Port #3 GND Pin 21
Administration Settings:
The following must be set for the engine data to be displayed:
1. Serial Port #number Function set to FADEC SBC 100
2. 15. Engine Module Config set to HW:EXT, NET:TXD