User guide

75
430W/530W ARINC 429 Verification Test
The 430W/530W communicates with the ARINC module using two separate
serial ARINC ports. VOR data is sent on one ARINC port and GPS data is
sent on the other ARINC port. You should verify that both ports are working
after wiring and configuring the EFIS and 430W/530W.
1. EFIS to AF-ARINC Module Communication Test
Boot the EFIS in CONFIG mode and select: 1. Admin Settings -> 21. Diagnostics -> 8. ARINC VOR Test
If the ARINC module is wired to the EFIS correctly it should find the adaptor and you should see the
Message Count increasing. If the EFIS does not find the adaptor the problem is between the AF-ARINC
adaptor and the EFIS and you should check the
following:
Power to the AF-ARINC module, you can remove
the AF-ARINC cover and check for a green light.
Wiring between the EFIS serial port and ARINC
Module.
Serial Port setup on the EFIS Admin Settings page.
2. ARINC to 430W/530W VOR Communication Test
If the ARINC VOR side is wired to the 430/530 correctly and configured you should see some or all of the
VOR data from the radio. Data shown is RED is flagged from the radio and caused by a week VOR
signal.
3. ARINC to 430W/530W GPS Communication Test
Select: 1. Admin Settings -> 21. Diagnostics -> 9. ARINC GPS
Test
If the ARINC GPS side is wired to the 430/530 correctly
and configured you should see some or all of the GPS
data from the radio. Data shown is RED is flagged from
the radio