430W/530W ARINC 429 Verification Test 
The 430W/530W communicates with the ARINC module using two separate 
serial ARINC ports. VOR data is sent on one ARINC port and GPS data is 
sent on the other ARINC port. You should verify that both ports are working 
after wiring and configuring the EFIS and 430W/530W. 
1.  EFIS to AF-ARINC Module Communication Test 
Boot the EFIS in CONFIG mode and select: 1. Admin Settings -> 21. Diagnostics -> 8. ARINC VOR Test 
If the ARINC module is wired to the EFIS correctly it should find the adaptor and you should see the 
Message Count increasing. If the EFIS does not find the adaptor the problem is between the AF-ARINC 
adaptor and the EFIS and you should check the 
following: 
  Power to the AF-ARINC module, you can remove 
the AF-ARINC cover and check for a green light. 
  Wiring between the EFIS serial port and ARINC 
Module. 
  Serial Port setup on the EFIS Admin Settings page. 
2.  ARINC to 430W/530W VOR Communication Test 
If the ARINC VOR side is wired to the 430/530 correctly and configured you should see some or all of the 
VOR data from the radio. Data shown is RED is flagged from the radio and caused by a week VOR 
signal. 
3.  ARINC to 430W/530W GPS Communication Test 
Select: 1. Admin Settings -> 21. Diagnostics -> 9. ARINC GPS 
Test 
If the ARINC GPS side is wired to the 430/530 correctly 
and configured you should see some or all of the GPS 
data from the radio. Data shown is RED is flagged from 
the radio 