User guide

76
ARINC Module Software Updating
Boot the EFIS in CONFIG mode and select: 1. Admin Settings -> 20. System Maintenance -> 3. Upgrade
ARINC Software
Procedure
1. Download the latest ARINC software
from the AFS support page.
http://www.advanced-flight-systems.com
2. Unzip the ARINC.zip file, and place the
ARINC.HEX file onto a SD card.
3. Insert the card into the unit and navigate
to the page shown at right.
4. Cycle power to the ARINC adaptor. If
the ARINC module is powered on the
same source as the EFIS the internal
EFIS battery should keep the EFIS
running during the power cycle.
5. Press the start button to begin loading
the new code. The screen will say,
“Loading….xxx”. Where xxx is the
number of bytes transferred.
6. When the screen prints “Done.”, you can remove the card and reboot the ARINC module.
7. Verify that the ARINC software version was updated from the following menu after the EFIS is running in
normal mode: [CHECK] -> [MAINT.] -> [ABOUT] The ARINC software version should be displayed in
the list.
Now the ARINC module is ready for use.