User guide
93 
Multiple Screen Setup 
Multiple screens (EFIS and Engine Monitor) can be connected together to enable data sharing by using a 
standard Ethernet cross over cable or Ethernet hub plugged into the back of the units. Once the screens are 
connected with the cable you will need to configure each screen for transmit and receive in the calibration 
menu. 
Every screen on the Network must have a unique IP Number, we use the following format for multiple 
screens: 
EFIS Screen in front of Pilot 
15. Network IP Number this screen    175 
Screen on CoPilot side 
15. Network IP Number this screen    176 
Screen #3 - MFD 
15. Network IP Number this screen    177 
The 16. Network IP Number Other screen setting  controls which other screen the EFIS data will be displayed from. 
Any screen that does not have an AHRS should have this set to the address of the remote screen with the AHRS that it 
will display EFIS data from or compare AHRS data with. 
Dual AHRS Configuration 
CAUTION 
For Dual AHRS cross checking to work you should always set the AHRS Module Config to TXD 
and the Network IP Number Other screen to the address of the remote AHRS. 
Multiple Screen Configuration Examples 
The following examples should help you configure your system: 
<Example #1> AF-3500EF EFIS and AF-3500EM Engine Monitor  
AF-3000/4000EF EFIS Screen #1 
1. Admin Settings 
12. Engine Module Config    HW:OFF, NET:RXD 
13. Air Module Config    HW:INT, NET:TXD 
14. AHRS Module Config    HW:INT, NET:TXD 
15. Network IP Number this screen    175 
16. Network IP Number Other screen  176 
AF-3000/4000EM Engine Monitor Screen #2 
1. Admin Settings 
12. Engine Module Config    HW:INT, NET:TXD 
13. Air Module Config    HW:OFF, NET:RXD 
14. AHRS Module Config    HW:OFF, NET:RXD 
15. Network IP Number this screen    176 
16. Network IP Number Other screen  175 
<Example #2> AF-3500EF EFIS and AF-3500EE EFIS-Engine Monitor (AHRS Cross Checking) 
AF-3000/4000EF EFIS Screen #1 
1. Admin Settings 
12. Engine Module Config    HW:OFF, NET:RXD 
13. Air Module Config    HW:INT, NET:TXD 
14. AHRS Module Config    HW:INT, NET:TXD 
15. Network IP Number this screen    175 
16. Network IP Number Other screen  176 
AF-3000/4000EE EFIS-Engine Monitor Screen #2 
1. Admin Settings 
12. Engine Module Config    HW:INT, NET:TXD 
13. Air Module Config    HW:INT, NET:OFF 