User Manual

6. Keyboard
The unit has a START key on the handle and a foil keyboard with the following
keys:
7. Operation
7.1 Power ON and OFF
To switch ON the unit press the A / ON/OFF key.
To switch OFF the unit press the A / ON/OFF key again
or stop operating the unit for 1 minute.
- the display goes off.
You can also switch ON the unit by pressing the START
button:
- the display goes on and the unit starts reading tags
while the START key is pressed.
7.2 Setting the TIME and DATE
The HH500 is equipped with a quartz clock that runs
even when the unit is off. Each reading gets a time
stamp.
For that the correct time and date must be set at all
times.
To set the time and date press and hold the TIME key for about 5 seconds:
- the display shows the date and time and the first character is blinking.
Enter the correct date and time with the keys 0..9. At the end press OK.
- the seconds are automatically set to 0 when you press OK.
The function of the keys are:
START to start reading or writing tags.
0..9 for manual entry of Owner, TAG_ID or data or to write action codes to the memory.
TYPE short pressed, to access manual tag ID entry with keys 0..9 and A..F for ISO 6B and EM tags
(no function for the others). If pressed long (>1 second) it will allow to change the tag type to be read.
OWNER Pressing this key will cause the reader to ask for a new OWNER or USER. A new record with the new
user is created in the memory when finished.
TIME short pressed, to display the time and date temporarily. Long pressed (>2 seconds) to access Date
and Time entry.
OK to finalize data entries or to exit FIND mode.
A / ON/OFF for switching the reader ON and OFF. When in data entry mode, to enter hex value ‘A’.
NOTE 1)
B / WRITE to set the reader to WRITE mode. When in data entry mode, to enter hex value ‘B’.
NOTE 1
C / READ to set the reader to READ DATA mode. When in data entry mode, to enter hex value ‘C’.
NOTE 1
D / FIND to set the reader to FIND mode. When in data entry mode, to enter hex value ‘D’.
E / IDs to set the reader to READ IDS mode. When in data entry mode, to enter hex value ‘E’.
NOTE 1
F / CLEAR to clear the tag counter. When in data entry mode, to enter hex value ‘F’.
NOTE 1
NOTE 1 : If the unit goes to sleep mode it will go back to READ IDs mode automatically.
0000
0000
2000-01-01
00:01
TYPE
O
WNER
K
TIME