7.3 Selecting the kind of tags to read
The unit must be ON for this function to be performed. The HH500 is capable of
reading the following protocols:
- EM
- ISO16000-6B
- EPC Class 0
- EPC Class 1
- EPC Class 1 Gen 2
- EPC 119
To select the type you desire press and hold for 1 second the TYPE key. The
display informs the current selected format(s).
The setting is automatically stored on the unit’s non-volatile memory.
7.4 Identifying the OWNER
In some applications the identification of the OWNER of some items is necessary
(ex. livestock). The HH500 can be configured to always ask for the OWNER ID
after waking up the unit. See chapter Configuration later in this manual.
OWNER IDs are stored in the record memory and enables the database software
to identify it as such.
To set a new owner, press the OWNER key (the unit
must be ON first).
- the display shows the OWNER entry mode.
- you can now type in the new owner ID using the keys
0..9. Owners can be identified by tags, by names or by
HEX codes (see configuration later in this manual
).
- to call back the previous owner, press OWNER key
again. The top line of the display shows the respective
ID.
- press OK when the entry is complete: a new record is
made in the memory with this entry.
Note : OWNER must be set at the first time you start the unit.(or reprogram it)
7.5 Reading TAG IDs
Each tag has a unique identification number – TAG ID.
To read the TAG ID proceed as follows:
- make sure the right format is selected.
- point the antenna of the reader to the area where
the tag is.
- press the START button.
The display shows the read TAG ID on the top line, the tag count is incremented
and a beep sounds to inform you that the reading was successful.
7.6 Entering codes to the reading
In some applications data can be added manually to the reading by typing in pre-
defined codes. For example, the number of items in a pallet can be added to the
reading at the material reception or the sex code of an animal can be added to the
reading after tagging the animal.
To do so, after reading the respective tag (the TAG ID is shown on the top line)
press the code keys you want to associate to this reading using the keys 0..9.
- you can enter as many codes as you wish.
- entries are confirmed by a beep and shown on the display.
- after download of the data to the database, the codes appear associated
to the tag read.
7.7 Writing data to tags
Some kinds of tags have an internal memory that can be written with user data.
Please check the tag characteristics with the manufacturer.
To program data into tags press the B / WRITE key
(the unit must be ON first).
- the unit goes to data entry mode
You must now enter the data you want to write to the
tag using the keys 0..9.
- the 0..9 keyboard works as the telephone keyboard
in text mode: one press for the first letter, 2 for the
next and so on.
- you must confirm each letter with OK.
- pressing ‘0’ twice to clear the previous letter.
- when all the text to write is input point the reader to
the tag and press the START button.
Owner
0000000000000000
Owner
058000SC13824961
0001
Write
ABC_
Write
06
Write
ISO+EM
EPC C0
EPC C1
EPC G2
EPC119