User's Manual

AFG ASIA ENGINEERING CO.LTD.
65/12 M.10 T.Tonpao A.Sankumpang
Chiangmai, Thailand 50130
Tel: +66 53 390 909
Fax: +66 53 390 910
Page 9
PR100
User manual
Released
Ref. - (PR100 readers) Rev. 1_01 2008-03-13
Picture 3.3.4 the position of the “DISPLAY” button
Once user presses the “DISPLAY” button, the operation will change to sequence below:
“ISO-6B READ ID(H)” -> “ISO-6B READ DATA(H)” -> “ISO-6B READ DATA(A)”
Or
“ISO-6B WRITE DATA(H)” -> “ISO-6B WRITE DATA(A)”
When user is in “ISO-6B WRITE DATA(A)” mode, the PR100 RFID reader will allow typing in
ASCII Characters (0 – 9, A – Z).
3.4 Reading other field of ISO18000/6C(EPC Class1 Gen2)
The PR100 RFID reader allows user to read 4 fields in ISO18000/6C(EPC Class1 Gen2) tags.
The fields are as below:
Reserve – the data such as “ACCESS CODE”, “KILL CODE”(read/write or read only).
EPC – EPC(ID) number of a tag (read/write/lock).
TID – tag’s manufacture number and/or serial number. This field is written from a
factory (read only).
USER DATA – reserves for user data (read/write/lock).
When user want to read EPC(ID),DATA(H),DATA(A),TID or Reserve in ISO18000/6B(EPC
Class1 Gen2) tags, just press the “TAG TYPE” button to select “EPC-G2” mode and then press
the “DISPLAY” button. The sequence after pressing the “DISPLAY” button is as below: