User's Manual

32
Stop operation (30)
Description: Stops or cancels all of operations working with the RF part (reading,
writing, locking and killing). After sending this command, the reader status will be
“Stopping RF Power and then “Standby” (3.6, page 10).
Type: Reader operation command.
Transmits from PC to PR110 UHF RFID READER:
Command Number (2
chars)
Parameter (0 char) Carriage return,
<CR>(1char)
30
-
<CR>
Where:
“30” is the command number.
Returns from PR110 UHF RFID READER:
Command Number (2
chars)
Parameter (0 chars) Carriage return,
<CR>(1char)
30 - <CR>
Where:
“30” is the echo of the command number.
Example: