User's Manual

Advanced ID Asia Engineering Co., Ltd Page | 9
5.4 Detailed Description
5.4.1 Get-Serial-Number (01-01)
This command returns the serial number of the reader.
Field-Value: String with variable length
Example:
PC -> Reader: 52 46 45 01 0101 02 00 04 cs
Reader->PC: 52 46 45 01 0101 02 04 03 03000015 04 cs
dataLength = 0x04 -> 4 Bytes
serialNumber = 0x03 0x00 0x00 0x15 -> “03-00-00-15”
5.4.2 Get-Reader-Type (01-02)
This command returns the reader type of the reader.
Field-Value: String with variable length
Example:
PC -> Reader: 52 46 45 01 0102 02 00 04 cs
Reader->PC: 52 46 45 01 0102 02 04 03 81010101 04 cs
dataLength = 0x04 -> 4 Bytes
readerType = 0x81 0x01 0x01 0x01 -> 81-01-01-01 -> PUR RM1