Operator`s manual

a d v a n c e d i l l u m i n a t i o n . c o m
P u l s a r 7 1 0 M a n u a l
the operator should contact Technical Support at Ai.
6.2 Error Codes
The codes are listed below in bold face with a description of the fault
indicated and a corrective action.
351 No lighthead detected.
Corrective action Be sure lighthead is plugged in to output connector.
Check wiring of lighthead to connector.
352 Signatech I ID1 resistance not within known range.
Corrective action –Verify that lighthead is equipped with Signatech I.
Check wiring of lighthead to connector. Check values of ID1
resistor in connector. Verify proper value with Ai.
353 Signatech I ID2 resistance is not within known range.
Corrective action – Same as 352.
354SignatechIIlightheaddenitiondataisinvalid.
Corrective action Check lighthead wiring to connector. Verify that the
SignatechIIidentierintegratedcircuit(EEPROM)ispresent
in the connector. It should be attached to pins 11, 12, and 13.
CallAiifidentierintegratedcircuitispresent,thewiringis
correct, and problem persists.
355 The maximum allowed LED junction temperature will be exceeded
with the set parameters.
Corrective action - Adjust the output current selected, the pulse width,
or the pulse repetition rate until safe operating conditioins
are achieved.
411Thespecieddrivechannelisinvalid.
Corrective action Select valid drive channel. Check to see if lighthead
wiring in connector is such that lighthead is connected to
selected channel.
Error codes 212 through 219 indicate that internal voltage levels are
not correct. If these, or any codes other than those listed above occur,
contact Technical Support at Ai for assistance. Under no circumstances
should the user attempt repairs on the unit.
29