Operator`s manual

a d v a n c e d i l l u m i n a t i o n . c o m
P u l s a r 7 1 0 M a n u a l
9. TriggerPins1and2arenowconguredtorecognizeaRS232/485
logic level trigger input signal.
S1 Functions:
POS 1 On: Trigger 1 is fed through to Trigger 3
Off: Trigger 1 and Trigger 3 are stand alone
POS 2 On: Trigger 2 is fed through to Trigger 4
Off: Trigger 2 and Trigger 4 are stand alone
POS3 On: AdditionallteringisprovidedbetweenTrigger1and
Trigger 2
Off: Noadditionallteringisprovided
POS 4 On: Trigger 1 is Sourcing Input
Off: Trigger 1 is Sinking Input
J13 Functions:
Pin 2 – Pin 3 Shunted
Trigger 1 and Trigger 2 are stand alone
Note: In this mode S1 POS 3 should be off.
Pin 2 – Pin 1 Shunted
Trigger 1 and Trigger 2 are one differential trigger
Note: In this mode S1 POS 4 should be off.
The factory default settings are as follows:
S1: POS 1 Off J13:
POS 2 Off Pin 2 – Pin 3 Shunted
POS 3 Off
POS 4 On
36