9. Replace the cover on the housing, taking care to clear the power
switch. Re-install the four retaining screws.
10. Reconnect all cables to the Pulsar 710
11. TriggerPins1and2arenowconguredto“passthrough”thetrigger
signals and output them on trigger pins 4 and 5 respectively.
S1 Functions:
POS 1 On: Trigger 1 is fed through to Trigger 3
Off: Trigger 1 and Trigger 3 are stand alone
POS 2 On: Trigger 2 is fed through to Trigger 4
Off: Trigger 2 and Trigger 4 are stand alone
POS3 On: AdditionallteringisprovidedbetweenTrigger1and
Trigger 2
Off: Noadditionallteringisprovided
POS 4 On: Trigger 1 is Sourcing Input
Off: Trigger 1 is Sinking Input
J13 Functions:
Pin 2 – Pin 3 Shunted
Trigger 1 and Trigger 2 are stand alone
Note: In this mode S1 POS 3 should be off.
Pin 2 – Pin 1 Shunted
Trigger 1 and Trigger 2 are one differential trigger
Note: In this mode S1 POS 4 should be off.
The factory default settings are as follows:
S1: POS 1 Off J13:
POS 2 Off Pin 2 – Pin 3 Shunted
POS 3 Off
POS 4 On
38
(4.50)
114.3
(2.00)
50.8
(1.34)
34.1
(4.69)
119.1
(7.60)
193.1
(7.38)
187.3
M6 NUT CHANNEL
MOUNTING SURFACE
4
5
POWER / TRIGGER / COMMUNICATION CABLE INTERFACE
MOUNTING SURFACE
(2.04)
51.8
LIGHT HEAD INTERFACE
MOUNTING SURFACE
2 INCHES MINIMUM SPACE REQUIRED FOR POWER /
TRIGGER / COMMUNICATION CABLE INSTALLATION.
ENSURE ADEQUATE SPACE IS AVAILABLE FOR ROTARY
SWITCH / DIP SWITCH ADJUSTMENT IF REQUIRED.
4.5 INCHES MINIMUM SPACE REQUIRED TO INSTALL
LIGHT HEAD INTERFACE CONNECTOR AND ALLOW FOR
CABLE CLEARANCE.
3. UNIT MUST BE INSTALLED IN SUCH A WAY AS
TO PROVIDE ADEQUATE AIR FLOW TO ENSURE
AGAINST OVERHEATING.
2. UNIT MAY BE MOUNTED IN ANY POSITION.
1. UNIT WEIGHT: 3.8LB / 1.7 KG
4
5