4.2.16 SW3 Output Relay Function
PS1 button is the “Enter” or “Change” command.
PS2 button is the “Next” command.
Select “NORMAL” the output relay becomes momentary contact.
Select “NORMAL+S” the output relay becomes momentary contact. Must press the green
START button together to work.
Select “TOGGLE” the output relay becomes toggled contact.
Select “TOGGLE&E” the output relay becomes toggled contact affected by the e-stop
command (output relay opens when e-stop button is pressed).
Select “PITCH” SW3 button becomes the “Pitch” function in Pitch & Catch Operation.
Select “PITCH&E” SW3 button becomes the “Pitch” function in Pitch & Catch Operation.
When Pitch command is initiated the receiver mains are disconnected.
Select “STOP” SW3 button becomes an auxiliary e-stop function. Press to disconnect the
receiver mains and press START button to reconnect the receiver mains.
When select Pitch & Catch function make sure you set the spare transmitter to the next
channel up and the receiver channel scanning to “02” (see section 4.2.4).
Important note: When one of the above is selected make sure the same SW3 button
function on transmitter is set to “NORMAL” (see section 4.1.12).