User's Manual

Page 33
432 mm
Control
Panel
1. For best reception the location of the receiver should be visible to the operator at all time.
2. The location selected should not be exposed to high levels of electric noise. Mounting the receiver
next to an unshielded variable frequency drive may cause minor interference. Always locate the
receiver as far away from variable frequency drive as possible.
3. Ensure the selected location has adequate space to accommodate the receiver
(refer to Fig. 19 on page 32). If an external antenna is used, to avoid the
possibility of antenna damage always locate the receiver where the antenna is
free from any obstacles from all directions (refer to diagram at right).
4. When installing an external antenna you must connect the SMA jack located
inside the receiver and make sure to set the jumper to “EXT” position (refer
to diagram below).
5. For better reception, make sure the receiver is in an upright position.
6. Drill two holes (10mm in diameter) on the control panel or location where the receiver is to be installed
(refer to Fig. 19 on page 32).
7. Make sure the two bolts are tightened after installation.
8. For system wiring please refer to page 31.
D. SYSTEM TESTING
1. Turn on the power source to the receiver and test the MAIN relay output by pressing the red emergency
stop button and observe that it properly opens and closes the mainline disconnect contactor.
2. Test the operation of each function to ensure it corresponds to the transmitter direction labels or the
pendent it is replacing.
3. Test the limit switches (if any) to see if they are working properly.
4. If your new remote control is replacing an existing pendant, make sure it is completely disconnected
and placed in a safe location to prevent unwanted control command.