User's Manual

Page 35
A
B
3rd
SPEED
e. In case of an emergency, press down the red emergency stop button will immediately disconnect
the receiver MAIN and as well as the transmitter power. To resume operation, rotate the red button
clockwise or counter-clockwise, it will pop up. Then rotate the power key-switch to START
position for up to 1.0 second to activate all transmitter push button functions and the receiver
MAIN. Please note that every time when you turn the transmitter power off and back on again or
after resetting the emergency stop button, all push button functions will be locked to avoid any
unintentional controls. For safety, initiating the START command after turning on the transmitter
power or after resetting the emergency stop button is strictly required. The receiver MAIN will
also be disconnected temporarily when the receiver encounters strong radio interference or when
the operator is controlling the crane or equipment beyond the transmitting range.
f. Turn off the transmitter power by rotating the power key counter-clockwise to “Off” position; it
will disconnect the transmitter power and the receiver MAIN altogether. Turn it further
counter-clockwise to release the key.
WARNING
Keep away interference source to make sure performance integrate..
2. A/B Selector Push Button Operating Procedure
Pressing the “Select A/B” push button will toggle between output relay A, B, A+B respectively. There
are 4 different types of Select A/B sequence available, please refer to page 11~13 for instructions on
how to set Select A/B functions.
3. 3
rd
Speed Push Button Operating Procedure
When a push button is hold at 2
nd
speed, pressing the 3
rd
Speed push button one time will activate the 3
rd
speed output relay (toggled). If the operator wants 2
nd
speed again, just press the 3
rd
Speed push button
one more time.