User's Manual

Flex 12ES/EX Standard, AB and Tandem Instruction Manual
September 2016
Page 28 of 43
F
1 101
Pitch & Catch (type B)
Receiver MAIN relays maintained closure
during switchovers
G
1 111
2 steps with Closed/Closed relay action
Example #1: Left button (set to function code A) / right button (set to function code B)  1 000 001
Example #2: Left button (set to function code C) / right button (set to function code D) 1 011 100
4.2.4. Jumper Settings
Jumper setting applies to functions such as the standard or
reversed logic A/B selector sequence, transmitter inline
pushbutton configurations, firmware version, system testing and
remote pairing methods.
Jumper Settings Function
JP3
(Opened)
Standard A/B selector sequence - Output
relay A activated at A position, output relay B activated at B position,
both relays activated at A+B position.
JP3
(Inserted)
Reversed logic A/B selector sequence - Output
relay B activated at A position, output relay A activated at B position,
both relays deactivated at A+B position.
JP4
(Opened)
JP5
(Opened)
Standard right/left pushbutton configuration
JP4
(Inserted)
JP5
(Opened)
Inline top/bottom pushbutton configuration for PB1 to PB8
JP4
(Opened)
JP5
(Inserted)
Inline top/bottom pushbutton configuration for PB1 to PB12
JP4
(Inserted)
JP5
(Inserted)
Inline top/bottom pushbutton configuration for PB1 to PB4
JP6
(Inserted)
System firmware version
JP7
(Inserted)
For system testing only (receiver MAIN relays disabled)
JP8
(Opened)
Receiver-to-transmitter remote pairing
(pressing the Pairing button required)
JP8
(Inserted)
Receiver-to-transmitter remote pairing
(pressing the Pairing button not required)