User's Manual
Page 32
>NORMAL
SW1 RLY SW1 RLY
NORMAL
>BACK
SW1 RLY
>STOP
>SW1 RLY
NORMAL NORMAL
>SW2 RLY
>TOGGLE
>TOGGLE&E
>NORMAL+S
>PITCH
>PITCH&E
>SW1 RLY
NORMAL
SW1 RLY
>NORMAL
4.2.14 SW1 Output Relay Function 
PS1 button is the “Enter” or “Change” command. 
PS2 button   is the “Next” command. 
Select “NORMAL” the output relay becomes momentary contact. 
Select “NORMAL+S” the output relay becomes momentary contact. Must press the green 
START button together to work. 
Select “TOGGLE” the output relay becomes toggled contact. 
Select “TOGGLE&E” the output relay becomes toggled contact affected by the e-stop 
command (output relay opens when e-stop button is pressed). 
Select “PITCH” SW1 button becomes the “Pitch” function in Pitch & Catch Operation. 
Select “PITCH&E” SW1 button becomes the “Pitch” function in Pitch & Catch Operation. 
When Pitch command is initiated the receiver mains are disconnected. 
Select “STOP” SW1 button becomes an auxiliary e-stop function. Press to disconnect the 
receiver mains and press START button to reconnect the receiver mains. 
When select Pitch & Catch function make sure you set the spare transmitter to the next 
channel up and the receiver channel scanning to “02” (see section 4.2.4). 
Important note: When one of the above is selected make sure the same SW1 button 
function on transmitter is set to “NORMAL” (see section 4.1.10). 