User's Manual

Page 40
>SW7 RLY
>PITCH&E
>PITCH
>BACK
SW7 RLY
NORMAL
NORMAL
>TOGGLE
SW7 RLYSW7 RLY
>NORMAL+S
>STOP
>TOGGLE&E
SW7 RLY
NORMAL
>NORMAL
>SW7 RLY
>NORMAL
>SAVE?
YES NO
4.2.22 SW7 Output Relay Function
PS1 button is the “Enter” or “Change” command.
PS2 button is the “Next” command.
Select “NORMAL” the output relay becomes momentary contact.
Select “NORMAL+S” the output relay becomes momentary contact. Must press the green
START button together to work.
Select “TOGGLE” the output relay becomes toggled contact.
Select “TOGGLE&E” the output relay becomes toggled contact affected by the e-stop
command (output relay opens when e-stop button is pressed).
Select “PITCH” SW7 button becomes the “Pitch” function in Pitch & Catch Operation.
Select “PITCH&E” SW7 button becomes the “Pitch” function in Pitch & Catch Operation.
When Pitch command is initiated the receiver mains are disconnected.
Select “STOP” SW7 button becomes an auxiliary e-stop function. Press to disconnect the
receiver mains and press START button to reconnect the receiver mains.
When select Pitch & Catch function make sure you set the spare transmitter to the next
channel up and the receiver channel scanning to “02” (see section 4.2.4).
Important note: When one of the above is selected make sure the same SW7 button
function on transmitter is set to “NORMAL” (see section 4.1.16).