    Epoch-S02 RF Repeater 
User Manual V1.1 
Figure 2.3 All Alarm Parameters from the Main Status 
 Window of the Epoch-S02 OMS V2.0 
In the event of a Hard Failure, the control board will shutdown the HPA for 30 
seconds and then turns on the HPA to check for a repeated Hard Fail occurrence. If 
the next two occurrences sense a Hard Fail, the control boards will shutdown the 
HPA for 1 hour (total of three consecutive hard fails). After 1 hour, the HPA will 
automatically come back alive and the control board will check if the Hard Fail alarm 
has cleared or not. If it has not, the same process will continue as mentioned above. 
2.3.1  General (Fixed Parameter) Alarms 
Alarm List  Soft Fail  Hard Fail Comments 
Over/Under Current  O  O 
Soft Fail: Less than 1 A @ under current 
Hard Fail: More than 6 A @ over current 
Over Temperature  O  O 
Soft Fail: < 158 ~ 185 °F 
Hard Fail: > 185 °F 
Synthesizer Lock  -  O  Synthesizer Unlock 
VSWR  -  O  > 1.5:1 
Low Isolation/Osc.  -  O  Repeater oscillation 
Table 2.3.1 General (Fixed Parameter) Alarms of the OMS V4.01 