User's Manual
Table Of Contents
- Installation Guide for Epoch-S02
- Environmental requirements
 - Warnings and Hazards
 - Tools and Recommendations for Installation
 - Epoch-S02 Parts List
 - Step by Step Instructions for Installation
 - User Manual V1.1 using OMS V4.01
 - Menu Structure
 - Using the Epoch-S02 OMS V4.01
 - Alarms
 - Default Control Settings
 - Maintenance Guide for Epoch-S02 OMS V4.01
 - Periodic Inspection Checklist
 - Preventive Measures for Optimal Operation
 - Troubleshooting
 - Epoch-S02 OMS V4.01 Scenarios
 - Heartbeat Scenarios
 - Warranty and Repair Policy
 - General Warranty
 - Specific Product Warranty Instructions
 - A.1 Minimum Requirements
 - A.2 Epoch-S02 OMS V4.01 Installation/Startup
 
 - Appendix B: Specifications
 
    Epoch-S02 RF Repeater 
User Manual V1.1 
MECHANICAL SPECIFICATIONS 
PARAMETERS  SPECIFICATIONS  COMMENTS 
Cabinet Size  15.75 x 17.72 x 7.85 
inches 
W x H x D 
Cabinet Weight  ≤ 50 lbs   
Cabinet Mount Type  Utility Pole Mount   
Antenna N-Type (F)   
Coupling  SMA (F)  30 dB 
Frame Ground  Hex Nut (M6)   
Connector 
Type 
Control  DB9 (M)   
Cooling  Convection   
Weatherproofing NEMA 4, IP65   
POWER SPECIFICATIONS 
PARAMETERS  SPECIFICATIONS  COMMENTS 
Main AC Power  100 to 240 VAC   
AC Frequency  45 to 65 Hz   
Power Consumption  ≤ 300 Watts   
AC Supply Protection  Fuse   
Output Voltage  12.0 VDC   
Endurance  ≥ 2 hour   
Main to 
Auxiliary 
Automatic 
Auxiliary to 
Main 
Automatic 
Auxiliary 
Power 
(Option) 
Battery 
Protection 
Internal Fuse   
Grounding  External Threaded Stud   
ENVIRONMENTAL SPECIFICATIONS 
PARAMETERS  SPECIFICATIONS  COMMENTS 
Operating Temperature  -22 ˚F to +122 ˚F 
Storage Temperature  -22 ˚F to +176 ˚F 
Humidity  10 to 85%, RH   
Advanced RF Technologies, Inc. Proprietary Document  Page 31 of 31 