User Manual
    Epoch-M1C RF Repeater 
User Manual V1.1 
Advanced RF Technologies, Inc. Proprietary Document  Page 19 of 38 
Uplink Tracking/Offset Modes 
Uplink tracking mode enables or disables the 
Uplink Tracking ON
 feature that 
sets the gain in the uplink equaling to the gain in the downlink. The tracking 
gain offset is the difference between the uplink and downlink gains. For 
example, if the downlink gain is 80 dB, the 
Uplink Tracking ON 
is checked, and 
the 
Uplink
Tracking Gain Offset
 is set to 3 dB, the uplink gain would be 77 dB.  
By default, the 
Uplink Tracking ON
 box is not checked.  If it was checked, then 
the default 
Uplink Tracking Offset
 is set to 3 dB. This means that the uplink gain 
will track the down link gain and will be 3 dB less. 
Control Item  Action  Setting Value 
Uplink Tracking ON  Set Uplink Tracking Mode  ON or OFF 
Uplink Tracking Offset  Set Tracking Gain Offset  0 ~ 10 dB @ 0.5 dB step 
Downlink/Uplink Gain 
The gain of the Epoch-M1C is the ratio of the input signal to the output signal.  
The gain may be set in both links. 
** The manual gain option is disabled when the AGC ON box is checked. 
  Reboot 
By clicking the “Reboot” button, similar to how the operation works in a PC, the 
control board of the repeater will restart itself. 
  Factory Setting 
Clicking on the “Factory Setting”
button resets the settings of the repeater to the 
original default factory settings as noted in the “Default Control Settings” in 
Section 2.4 on page 28. 
** You will lose your current saved settings once you click on Factory Setting. 
Table 3 - Uplink Tracking Mode and Tracking Gain Offset Range