In the event of a hard fail alarm, the control board will shut down the HPA (both 
uplink & downlink) for 30 seconds and then turn on the HPA to check for a repeated 
hard fail occurrence. If the hard fail alarm persists for up to four consecutive 
occurrences, the control board will shut down the HPA for 20 minutes (total of five 
consecutive hard fails). After 20 minutes, the HPA will automatically come back alive 
and the control board will check if the Hard Fail alarm has cleared. If it has not, the 
same process will continue as mentioned above. 
** The alarms can also be viewed on the front panel of the repeater by clicking 
the VFD button. Please refer to Appendix B for more detailed information. 
** Epoch-M1C also supports AAI (Auxiliary Alarm Input). Please refer to Section 
1.1.2 on Page 6. 
2.3.1  General (Fixed Parameter) Alarms 
Alarm List  Soft Fail  Hard Fail Comments 
Over/Under Current  O  O 
Soft Fail: Less than 0.5 A @ under current 
Hard Fail: More than 4.7 A @ over current 
Over Temperature  O  O 
Soft Fail: 158 ~ 185 °F 
Hard Fail: > 185 °F 
Synthesizer Lock  -  O  Band selection will not work properly 
VSWR  -  O  > 1.5:1 
RF Power  -  O 
Will occur in the event of any 
Hard Fail alarm 
Table 7 - General (Fixed Parameter) Alarms of the Epoch-M1C Software 
Figure 13 - All Alarm Parameters Supported by Epoch-M1C 