User Manual
    Epoch-M1C RF Repeater 
User Manual V1.1 
Advanced RF Technologies, Inc. Proprietary Document  Page 31 of 38 
4.2 Common Installation Problems 
Problem Possible Solution 
USB port is 
not being 
recognized 
You would need to install the driver for the USB cable which can be 
found with the CD that comes with the repeater. 
The power 
green LED on 
the front panel 
is not lit. 
Check if the power switch is turned on. Also verify if the power cord is 
securely connected to the repeater. Make sure there is no power 
outage. 
GUI Software & 
Laptop - No 
Communication 
The very first time during installation, once you connect the USB cable 
to the repeater and the laptop, the PC will automatically detect a new 
hardware has been added in the system and will prompt you to install 
the driver which can be found in the CD. The driver needs to be 
installed only once. 
Status Window – 
Weak Signal or 
Donor RSS 
Check that the donor and server antennas are connected to the proper 
antenna ports on the repeater. 
Reposition or rotate the donor antenna until a stronger signal is 
received. 
Low Isolation or 
Oscillation 
Increase the separation between the donor and server antennas by 
moving the antennas around or by rotating them. 
Downlink/Uplink 
VSWR Alarm 
Check the cabling because RF signals may be leaking and also verify 
that the connectors are tightly secured. 
Downlink/Uplink 
Input Power 
Overload Alarm 
Add an attenuator after the donor/server antenna to reduce the strong 
donor/server signal coming into the repeater. 
If the repeater is connected to a DAS, there is a good chance the DAS 
system could cause a strong signal to come in on the uplink side of 
the repeater, causing an 
Uplink Input Power Overload
 alarm. If this 
happens, add an attenuator on the uplink side of the repeater or 
control the signal coming in from the DAS. 
Try to reduce the AGC Power Level using the GUI software. 
An oscillation in the system could cause this alarm. Check if there is 
sufficient separation between the donor and the server antennas. 
Downlink/Uplink 
Over Power 
Alarm 
Add an attenuator after the donor/server antenna to reduce the strong 
donor/server signal coming into the repeater. 
An oscillation in the system could cause this alarm. Check if there is 
sufficient separation between the donor and the server antennas. 
Table 12 – Troubleshootin
g
 Ti
p
s