3.2  Alarms 
Table 3-2  Alarms Threshold 
Parameters  Remark 
AC Fail 
Power supply is not operating within specs. (4 seconds) 
DC Fail 
Power supply is not operating within specs. (4 seconds) 
Fan1, Fan2 Fail 
System has detected an issue with each fan. (4 seconds) 
Temperature 
Module is above the normal operating temperature. (4 seconds) 
Over Temperature [ Soft: 80~87 C, Hard: Above 87 C] 
Current 
Power supply is not operating within specs. (4 Second) 
Over Current [ Hard: Above 20A] 
System Halt  System is in a shutdown state due to a hard fail alarm. (10 times) 
DSP Fault 
System has detected an issue with the internal DSP chip. (Cannot 
communication with DSP) 
OSC 
Oscillation detected. Alarm is only present when one-time 
oscillation check is performed. 
DL Signal not detected  DL signal is below the specified level. (default: -90dBm, 4 seconds) 
DL Signal Low  DL signal is below the specified level. (default: -85dBm, 4 seconds) 
Input Overload 
Input signal is above the threshold. (4 seconds) 
(Soft: DL -10dBm/UL -12dBm, Hard: DL -8dBm/UL -10dBm) 
Out of band Overload 
Out of band signal is above the threshold. (4 seconds) 
(Soft: DL -10dBm/UL -12dBm, Hard: DL -8dBm/UL -10dBm) 
Synthesizer Lock Fail 
Issue with internal PLL(4 seconds) 
DL RF Power 
Input + gain does not match the output level 
(default delta of 6 dB) 
Overpower 
Output level is above the max output levels 
AGC On case(Soft: AGC Level+ 1~2dB, Hard: AGC Level + >2dB) 
AGC Off case(Soft: max output level+ 1~2dB, Hard: max output 
level + >2dB) 
VSWR 
Power is being reflected back to the repeater. Threshold = output 
power - 8dB. For example, if the repeater is outputting 24dBm, 
then if the system detects 16dBm of return power, then the VSWR 
will be triggered.(Triggered in case of over +15dBm output power) 
Door 
Door alarm set : Door open 
Door alarm clear : Door close 
Advanced RF Technologies, Inc.     20   