3. ALARMS
3.1 Message Board Alarms and Notification
Table 3-1 Message Board Alarms and Notification
Parameters
Remark
AC Fail
Power supply is not operating within specs
DC Fail
Power supply is not operating within specs
Fan[1/2] Fail
System has detected an issue with the fan1 and fan2
Temperature
Module is above the normal operating temperature
Current
Power supply is not operating within specs
System Halt
System is in a shutdown state due to a hard fail alarm
DSP Fault
System has detected an issue with the internal DSP chip
OSC
Oscillation detected
DL Signal not detected
DL signal is below the specified level
DL Signal Low
DL signal is below the specified level
Input Overload
Incoming in-band DL or UL signal is too strong
Out of band Overload
Incoming out-band DL or UL signal is too strong
Synthesizer Lock Fail
Issue with internal PLL
DL RF Power
Input + gain does not match the output level (above delta of 6 dB)
Overpower
Output level is above the max output levels
VSWR
Power is being reflected back to the repeater
Heartbeat
Heartbeat
Reboot
Reboot
Factory setting
Factory setting
Door
Door alarm set/clear.