User's Manual
AXM700 Repeater
User Manual V0.2
Page | 23
Manual Gain Control
• Downlink Gain: Allows the DL gain to be adjusted manually when AGC is OFF
• Uplink Gain: Allows the UL gain to be adjusted manually when AGC is OFF
• Downlink AGC Level: Allows the user to set the DL gain when AGC is enabled
• Uplink AGC Level: Allows the user to set the UL gain when AGC is enabled
• Uplink Tracking Offset: This offset value determines how many dB lower the uplink gain value will be relative to the
downlink gain value
Alarm Setting
• Downlink Signal Low: Allows the user to specify how weak the signal can be before triggering a “Downlink Signal Low” soft-
fail alarm
• Downlink Signal Not Detected: Allows the user to specify the how weak the signal can be before triggering a “Signal Not
Detected” soft-fail alarm
• Downlink RF Power: Allows the user to set a maximum deviation value for the downlink RF power
o For example, if the input signal is -50 dBm and the gain is set to 60 dB, the expected output power should be 10 dBm.
If the Downlink RF Power alarm value is set to 6dB, then if the output power is below 4 dBm, then this will trigger a
soft-fail alarm
• Tamper Detected: Allows the tamper detection feature to be enabled or disabled
• Reset Engaged: Allows the Reset Engaged functioned to be enabled or disabled