Manual Gain Control
Downlink Gain: Allows the DL gain to be adjusted manually when AGC is OFF
Uplink Gain: Allows the UL gain to be adjusted manually when AGC is OFF
Downlink AGC Level: Allows the user to set the DL gain when AGC is enabled
Uplink AGC Level: Allows the user to set the UL gain when AGC is enabled
Uplink Tracking Offset: This offset value determines how many dB lower the uplink gain value will be relative to the
downlink gain value
Alarm Setting
Downlink Signal Low: Allows the user to specify how weak the signal can be before triggering a “Downlink Signal Low” soft-
fail alarm
Downlink Signal Not Detected: Allows the user to specify the how weak the signal can be before triggering a “Signal Not
Detected” soft-fail alarm
Downlink RF Power: Allows the user to set a maximum deviation value for the downlink RF power
o For example, if the input signal is -50 dBm and the gain is set to 60 dB, the expected output power should be 10 dBm.
If the Downlink RF Power alarm value is set to 6dB, then if the output power is below 4 dBm, then this will trigger a
soft-fail alarm
Tamper Detected: Allows the tamper detection feature to be enabled or disabled
Reset Engaged: Allows the Reset Engaged functioned to be enabled or disabled