User Manual

Epoch-HP RF Repeater
User Manual V1.1
Advanced RF Technologies, Inc. Proprietary Document Page 27 of 36
3.3 Alarms
All the various alarms that are supported by Epoch-HP can be viewed by clicking the
“Alarm” button on the Status Window. If a soft fail alarm should occur, the alarm of
concern would be highlighted in yellow. In the same manner, the corresponding
hard fail alarm would be highlighted in red. In order to find out what is causing the
alarm(s), simply place the mouse cursor over the highlighted yellow or red alarm box
(Note: only applicable to some of the alarms)
and a tool tip message will appear,
displaying the threshold value and the current measured value. To update the
window, click the “Refresh” button.
Control Menu
General
Setting
Alarm
Setting
Reboot
Factory Setting
Manual Gain Control*
AGC Level Control*
Uplink Tracking Offset
Periodic Time
RSSI*
Input Overload*
Figure 15 - Variable Parameters in the Epoch-H V1.X
Figure 16 - All Alarm Parameters Supported by Epoch-H V1.X