The example below distinguishes the difference between an over power soft
failure and an over power hard failure:
The threshold value for the downlink over power parameter is set to 45.0 dBm
(factory set value for the 20 W model), a Hard Fail alarm would occur if the
downlink over power value was greater than 45.0 dBm (43 dBm is the maximum
composite power allowable). Similarly, a Soft Fail alarm would occur if the
downlink over power value was greater than 44.0 dBm but less than 45.0 dBm.
Vice versa, the same example is also applicable in the uplink side.
3.4 Default Control Settings
3.4.1 Default General Setting
Control Item Setting Value
AGC Mode ON
Downlink/Uplink HPA Mode
ON
Uplink Tracking Mode ON
Downlink/Uplink Gain 80 dB
Downlink/Uplink AGC Level
DL: 37/40/43 dBm
UL: 27/30/33 dBm
(depending on model)
Tracking Gain Offset 3 dB
a. When
Uplink Tracking ON
mode is enabled by default, the
Tracking Gain
Offset
is set to 3 dB.
b. When
AGC ON
mode
is enabled, by default, the
Downlink/Uplink AGC
Level
is set to 37/40/43 dBm (depending on model).
3.4.2 Default Alarm Setting
Setting Value
Control Item
Downlink Uplink
RSSI -95 dBm -110 dBm
Input Overload -30 dBm -30 dBm
Heartbeat On/Off ON
Heartbeat Time 20 minutes
Table 10 - Default Alarm Parameter Values of the Epoch-H V1.X
Table 9 - Adjustable Alarm Settings of the Epoch-H V1.X