Either or both HPAs can be turned off for troubleshooting purposes during an
installation process.
Uplink Tracking/Offset Modes
Uplink tracking mode enables or disables the
Uplink Tracking ON
feature that
sets the gain in the uplink equaling to the gain in the downlink. The tracking
gain offset is the difference in the uplink and downlink gains. For example, if
the downlink gain is 80 dB, the
Uplink Tracking ON
is checked, and the
Uplink
Tracking Gain Offset
is set to 3 dB, the uplink gain would be 77 dB.
By default, the
Uplink Tracking ON
box is not checked. If it was checked, then
the default
Uplink Tracking Offset
is set to 3 dB. This means that the uplink gain
will track the down link gain and will be 3 dB less.
Control Item Action Setting Value
Uplink Tracking ON Set Uplink Tracking Mode ON or OFF
Uplink Tracking Offset Set Tracking Gain Offset 0 ~ 25 dB @ 0.5 dB step
Downlink/Uplink Gain
The gain of the Epoch-S02-19002W is the ratio of the input signal to the output
signal. The gain may be set in both links.
** The manual gain option is disabled when the AGC ON box is checked.
System Reboot
By clicking the “Reboot” button, similar to how the operation works in a PC, the
control board of the repeater will restart itself.
System Factory Setting
Clicking on the “Factory Setting
button resets the settings of the repeater to the
original default factory settings as noted in the “Default Control Settings” in
Section 2.4 on page 26.
** You will lose your current saved settings once you click on “System Factory
Setting”
Table 2 - Uplink Tracking Mode and Tracking Gain Offset Range