In the event of a hard fail alarm, the control board will shutdown the HPA (both 
uplink & downlink) for 30 seconds and then turns on the HPA to check for a 
repeated hard fail occurrence. If the next two occurrences sense a hard fail, the 
control board will shutdown the HPA for 20 minutes (total of three consecutive hard 
fails). After 20 minutes, the HPA will automatically come back alive and the control 
board will check if the Hard Fail alarm has cleared. If it has not, the same process 
will continue as mentioned above. 
2.3.1  General (Fixed Parameter) Alarms 
Alarm List  Soft Fail Hard Fail Comments 
Over/Under Current  O  O 
Soft Fail: Less than 0.5 A @ under current 
Hard Fail: More than 7.5 A @ over current 
Over Temperature  O  O 
Soft Fail: 158 ~ 185 °F 
Hard Fail: > 185 °F 
Synthesizer Lock  -  O  Band selection will not work properly  
VSWR  -  O  > 1.5:1 
Low Isolation/OSC.  -  O  Repeater will be in an oscillating state 
RF Power  -  O 
Will occur in the event of any  
Hard Fail alarm 
2.3.2  Downlink/Uplink Alarms 
Alarm List  Soft Fail Hard Fail Remark 
RSSI  O  - 
Input Power Overload  O  - 
Downlink 
(Forward) 
Over Power*  O  O 
RSSI  O  - 
Input Power Overload  O  - 
Uplink 
(Reverse) 
Over Power*  O  O 
Alarms will turn on if the 
value is not within operable 
limits specified in the 
Control Alarm Setting 
Window. 
Note: The Over Power 
parameter is fixed and 
cannot be modified by 
the user. 
Table 5 - General (Fixed Parameter) Alarms of the OMS V4.XX 
Table 6 – List of Alarm Settings of the OMS V4.XX