    Epoch-S02-8002W RF Repeater 
User Manual V1.0 
Advanced RF Technologies, Inc. Proprietary Document  Page 20 of 33 
2.1.3.2  Alarm Setting Window 
Control Item  Action Downlink Uplink 
Downlink/Uplink 
RSSI  Sets Low RSSI Alarm Level  -120 ~ -60 dBm  -120 ~ -60 dBm 
Downlink/Uplink 
Input Overload 
Sets Input Overload Level  -50 ~ -20 dBm  -50 ~ -20 dBm 
RSSI 
The RSSI alarm is the minimum RSSI value that the Epoch-S02-8002W requires to 
ensure optimal coverage. The RSSI alarm will go off when the RSSI is lower than 
the threshold value (refer to the RSSI value in the Alarm Setting Window). The 
threshold RSSI value can also be adjusted manually @ 0.5 dB step (range is 
shown in Table 3 on page 19). 
Input Overload 
A 
Downlink/Uplink Input Overload
 alarm occurs when the input signal strength 
to the Epoch-S02-8002W exceeds the threshold value (refer to the 
Uplink/Downlink Input Overload
 values in the Alarm Setting window). 
Figure 8 - Alarm Setting Window of the Epoch-S02 OMS V1.XX
Table 3 - Alarm Threshold Values 