User's Manual

SDR Repeater
User Manual V0.4
Page | 12
3.1.3 Message Board Alarms and Notification
Parameters Remark
Communication failure Internal Communication failure
RMF Field replaceable module failure
RESET Reset alarm
Heartbeat Heartbeat
OSC Oscillation detected
UL RSSI fail Power at coverage port too high
UL PLL fail UL Synthesizer failure
H/W fail Hardware failure
S/W fail Software failure
UL Emission fail UL Out-of-band emissions out of spec
DL RSSI fail Donor Power too high/low
ISO fail Low isolation
DL PLL fail DL Synthesizer failure
DL Spur fail DL Spurious emissions out of spec
Interfere Interferer power exceeded
Link Fail Communication error between the module and NMS
Over Temperature Module is above the normal operating temperature
Under Temperature Module is below the normal operating temperature
Fan Fail System has detected an issue with the fan
System Halt System is in a shutdown state due to a hard fail alarm
DL Signal not detected DL signal is below the specified level
DL Signal Low DL signal is below the specified level
Outband overload System has detected a strong out of band signal
Input overload In-band incoming signal strength is above max input level
Synthesizer Lock Fail Issue with internal system amp
DSP Fault System has detected an issue with the internal DSP chip
DL RF Power Input + gain does not match the output level (above delta of 6 dB)
Overpower Output level is above the max output levels
DL Oscillation Alarm Oscillation has been detected in the system
VSWR Power is being reflected back to the repeater
AC Fail Power supply is not operating within specs
DC Fail Power supply is not operating within specs
Over Current Power supply is not operating within specs