User's Manual
SDR Repeater 
  User Manual V0.4 
Page | 12  
3.1.3 Message Board Alarms and Notification 
Parameters  Remark 
Communication failure Internal Communication failure 
RMF  Field replaceable module failure 
RESET Reset alarm 
Heartbeat Heartbeat 
OSC Oscillation detected 
UL RSSI fail  Power at coverage port too high   
UL PLL fail  UL Synthesizer failure 
H/W fail  Hardware failure 
S/W fail  Software failure 
UL Emission fail  UL Out-of-band emissions out of spec 
DL RSSI fail  Donor Power too high/low 
ISO fail  Low isolation 
DL PLL fail  DL Synthesizer failure 
DL Spur fail  DL Spurious emissions out of spec 
Interfere Interferer power exceeded 
Link Fail  Communication error between the module and NMS 
Over Temperature  Module is above the normal operating temperature 
Under Temperature  Module is below the normal operating temperature 
Fan Fail  System has detected an issue with the fan 
System Halt  System is in a shutdown state due to a hard fail alarm 
DL Signal not detected  DL signal is below the specified level 
DL Signal Low  DL signal is below the specified level 
Outband overload  System has detected a strong out of band signal 
Input overload  In-band incoming signal strength is above max input level 
Synthesizer Lock Fail  Issue with internal system amp 
DSP Fault  System has detected an issue with the internal DSP chip 
DL RF Power  Input + gain does not match the output level (above delta of 6 dB) 
Overpower  Output level is above the max output levels 
DL Oscillation Alarm  Oscillation has been detected in the system 
VSWR  Power is being reflected back to the repeater 
AC Fail  Power supply is not operating within specs 
DC Fail  Power supply is not operating within specs 
Over Current  Power supply is not operating within specs 