User's Manual

SDR Repeater
User Manual V0.4
Page | 27
4.3.2.2 System
Reboot: Clicking the reboot button will have the following popup show up:
Click OK to reboot the repeater or click Cancel to exit out
Factory Setting: Resets the repeater to the original factory settings
4.3.2.3 Heartbeat Time
o Allows the user to enable or disable heartbeats from being sent out and also specify the time interval
4.3.2.4 Alarm Reporting Time
This section allows the user to specify the reporting time of the following alarms; Over Current, Over
Temperature, VSWR, RSSI at Donor, and RF Power. If the alarm is set to 5 mins, then the system will send
out an SNMP trap only if the alarm is continually present for a 5 minute period. If the alarm clears within this 5
minute period, then the SNMP trap will not be sent out. When the alarm reporting time is set to 0 min, the
SNMP trap will be set out immediately once the alarm is triggered. The alarm should be set to 0 min, only
when testing the monitoring function. Otherwise, all alarms should be set to 5 mins for normal operation.