User's Manual
Table Of Contents
- ADAM-2000 Series
- 1 Understanding Your System
- 1.1 Introduction
- Figure 1.1 ADAM-2000 Series System Architecture
- Figure 1.2 ADAM-2000 Series Outdoor Range Distance
- 1.1.1 IEEE 802.15.4 Wireless Standard
- 1.1.2 Wireless Sensor Network
- 1.1.3 Low-power Consumption and Battery-Powered Design
- 1.1.4 Sensor Embedded Design
- 1.1.5 Wireless Signal Indicator
- 1.1.6 Industrial Standard Modbus Protocol
- 1.1.7 SCADA Software Support
- 1.1.8 Advantech Software Alignment
- 1.2 Specifications
- 1.3 Dimensions
- 1.4 Mounting
- 1.5 Wiring & Connections
- 1.1 Introduction
- 2 Selecting Your Hardware
- 3 Installation Guide
- 4 Software Configuration Guide
- 4.1 System Software Configuration Utility
- 4.2 Installing ADAM.NET Utility Software
- 4.3 ADAM.NET Utility Operation
- Figure 4.1 ADAM.NET Utility Operation Window
- Figure 4.2 ADAM.NET Utility Toolbar
- 4.3.1 Search and Configure the ADAM-2000 Series
- Figure 4.3 ADAM-2000 Series ADAM .NET Utility Support
- Figure 4.4 Search the USB interface ADAM-2000 devices on the host PC for the virtual COM port.
- Figure 4.5 Search the COM port for the ADAM-2000 devices.
- Figure 4.6 Searching the network dialog
- Figure 4.7 Searching the ADAM-2000 coordinators.
- Figure 4.8 ADAM-2000 devices lists on the Tree View and Information page.
- Figure 4.9 The overview of ADAM-2000 end devices.
- Figure 4.10 The overview of ADAM-2000 routers
- 4.3.1.1 Gateway - ADAM-2520Z
- 4.3.1.2 Router - ADAM-2510Z
- 4.3.1.3 End Device - ADAM-2017, ADAM-2031Z, ADAN-2051Z, ADAM-2051PZ
- Figure 4.16 Information Page of ADAM-2051Z
- Figure 4.17 Wireless Configuration page of ADAM-2051Z
- Figure 4.18 The Device Status page of the ADAM-2051Z
- Figure 4.19 The Signal page of the ADAM-2051Z
- Figure 4.20 Information Page
- Figure 4.21 Wireless Configuration Page
- Figure 4.22 Device Status Page
- Figure 4.23 Sensor Page
- 4.3.2 Network Topology of ADAM-2000 Series
- A Module Introduction
- B ADAM-2000 Series Functions
- C Troubleshooting
- 1 Understanding Your System
ADAM-2000 Series User Manual 28
3.3.4 Pairing
In the Initial Mode, Routers and End Devices must be associated with the corre-
sponding Coordinator. The function is for Router and End Devices only.
1. Press the Function Button 5 times to enter the change Pair ID mode.
2. Status LED blinks
3. Level Index LED turns on to indicate Pair ID.
4. Press the Function Button once to change Pair ID.
5. Press and hold the Function Button for over 3 seconds to save and confirm the
Pair ID.
6. Press the Function Button 3 times to associate with specific Pair ID Coordinator.
7. Error LED turns off when it join a PAN.
3.3.5 Reboot
Press the Function Button for over 3 seconds to reboot the device.