ATM-4023 4U Height, 19” Rackmount Industrial Chassis with 6.
Copyright The documentation and the software included with this product are copyrighted 2004 by Advantech Co., Ltd. All rights are reserved. Advantech Co., Ltd. reserves the right to make improvements in the products described in this manual at any time without notice. No part of this manual may be reproduced, copied, translated or transmitted in any form or by any means without the prior written permission of Advantech Co., Ltd. Information provided in this manual is intended to be accurate and reliable.
Product Warranty (1 year) Advantech warrants to you, the original purchaser, that each of its products will be free from defects in materials and workmanship for one year from the date of purchase. This warranty does not apply to any products which have been repaired or altered by persons other than repair personnel authorized by Advantech, or which have been subject to misuse, abuse, accident or improper installation.
CE This product has passed the CE test for environmental specifications when shielded cables are used for external wiring. We recommend the use of shielded cables. This kind of cable is available from Advantech. Please contact your local supplier for ordering information. FCC Class A This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules.
Packing List Before setting up the system, check that the items listed below are included and in good condition. If any item does not accord with the table, please contact your dealer immediately. 1. One ATM-4023 industrial workstation with 6.4” flat panel display 2. One accessory box, including: - One HMI manual and drivers CD-ROM - Cardboard Warranty - Flat gray cable for 3.5. HDD and slim CD-ROM - Two piece slim CD-ROM holders.
11. If the equipment is not used for a long time, disconnect it from the power source to avoid damage by transient overvoltage. 12. Never pour any liquid into an opening. This may cause fire or electrical shock. 13. Never open the equipment. For safety reasons, the equipment should be opened only by qualified service personnel. 14. If one of the following situations arises, get the equipment checked by service personnel: a. The power cord or plug is damaged. b.
The sound pressure level at the operator's position according to IEC 7041:1982 is no more than 70 dB (A). DISCLAIMER: This set of instructions is given according to IEC 704-1. Advantech disclaims all responsibility for the accuracy of any statements contained herein. Wichtige Sicherheishinweise 1. 1. Bitte lesen sie Sich diese Hinweise sorgfältig durch. 2. Heben Sie diese Anleitung für den späteren Gebrauch auf. 3. Vor jedem Reinigen ist das Gerät vom Stromnetz zu trennen.
13. Öffnen Sie niemals das Gerät. Das Gerät darf aus Gründen der elektrischen Sicherheit nur von authorisiertem Servicepersonal geöffnet werden. 14. Wenn folgende Situationen auftreten ist das Gerät vom Stromnetz zu trennen und von einer qualifizierten Servicestelle zu überprüfen: a - Netzkabel oder Netzstecker sind beschädigt. b - Flüssigkeit ist in das Gerät eingedrungen. c - Das Gerät war Feuchtigkeit ausgesetzt.
Contents Chapter 1 General Information ....................................... 2 1.1 1.2 1.3 1.4 1.5 1.6 Chapter Introduction ....................................................................... 2 General Specifications....................................................... 3 Passive Backplane Options ............................................... 4 CPU Card Options............................................................. 4 System Regulation........................................................
A.2 A.3 A.4 A.5 Figure A.1:PCA-6108P8-0A1: 8-slot Pure PCI backplane, 8 PCI, Rev.A101 22 Table A.1:Connector Descriptions .............................. 23 Connector Pin Definitions............................................... 24 PCI Routing Table........................................................... 24 Mechanical Dimensions .................................................. 25 Note .................................................................................
CHAPTER 1 2 General Information This chapter introduces ATM-4023 and its usage.
Chapter 1 General Information 1.1 Introduction The ATM-4023 IA Master series is based on a 4U high, 19” rack-mount industrial workstation with a 6.4" VGA color TFT LCD display and 8 expansion slots, as well as an optional CD-ROM drawer available upon request. It is designed as all-in-one and cost-effective enhanced solution for both traditional Industrial PC use and new industrial automation control.
1.2 General Specifications Physical • Housing: Heavy duty steel chassis • Paint Color: Pantone 4C 2X Black, textured • Dimensions: 482(W) x 173(H) x 266(D) mm (19" x 6.9" x 10.5") • Weight: 12 kg (326.4 lb) LCD Display • 6.4” Color TFT LCD Panel • 640 x 480 VGA Resolution • Brightness: 300 nits Power Supply:AC Input 100-240 V, 60-50 Hz, 6-3 A Add-on Card Length:Half Size Hard Drive Bay: • 1 x Front accessible slim-type CD-ROM Drawer (option) • 2 x 3.
1.3 Passive Backplane Options PCA-6108E (rev.C1): 8 Slot PC-Bus (8 ISA) Passive Backplane PCA-6108P8 (rev.A1):8 Slot PC-Bus (8 PCI) Passive Backplane 1.4 CPU Card Options PCI-6872F-00A1: PIII Graded, PCI Socket 370 Slot PC PCI-6870F-00A1: PIII Graded, PCI Socket370 815E Slot PCA-6774F-02A1: PIII Graded, ISA Socket 370 Slot PC PCA-6751-F0B2: P 266, ISA 586 Slot PC Part Number CPU Slot RAM VGA LAN USB CFC PC-104 (MB) PCI-6872F-00A1 PIII 1.
1.5 System Regulation Model No. Description ATM-4023H0-2Z 8 ISA slot Industrial Automation platform with 6.4” LCD /4U /Half Size/Front Wiring/ PCA-6108E (rev.C1) / 250W ATM-4023H8-2Z 8 PCI slot Industrial Automation platform with 6.4” LCD /4U /Half Size/Front Wiring/ PCA-6108P8 (rev.A1) / 250W ATM-4023H8-A1 8 PCI slot Industrial Automation platform with 6.4” LCD /4U /Half Size/Front Wiring/ PCA-6108P8 (rev.A1) / PCI-6872F00A1(PIII) / 250W ATM-4023H8-A2 8 PCI slot Industrial Automation platform with 6.
1.6 Dimensions 90 266 284.5 27.7 132 446 482 465 101.6 35.6 ATM-4023 User Manual 6 174.9 174.
CHAPTER 2 2 System Setup This chapter shows how to setup your card and install accessories.
Chapter 2 System Setup 2.1 System Installation Warning Before starting the installation process, be sure to shut down all power from the chassis. Do this by turning off the power switch, and unplugging the power cord from the power outlet. If in doubt, consult with an experienced technician. 2.1.1 Attaching the Handles The handles for the front panel are in the accessory box. To install the handles, secure them to the front panel with the provided screws. 2.1.
2.1.3 Chassis Front and Rear Sections Facing the front of the ATM-4023, you will find a 6.4" TFT display module that has five control keys on either side of the LCD screen. On the right, there is a cover for the cable wiring. There is also an optional slimtype CD-ROM drawer under the chassis. The front panel interface is used for system reset, power, USB port. There are also LED indicators for power, HDD data access, external keyboard/mouse, and OSD controls. Please refer to Figure 2.2. Figure 2.
Figure 2.4: Rear View 2.1.4 I/O Interface • Power On/Off Switch: Use this switch to turn on/off the system power. • System Reset: Press this switch to reinitialize the system. This switch functions like a hardware reset button. • Power LED Indicator: This light is on while the power is turned on. • HDD LED Indicator:This light is on when the HDD is accessing data. • USB ports: Use this port to connect any USB interface device to the system. • KB/MS IN: Integrated PS/2 type 6-pin keyboard and mouse port.
Figure 2.5: HDD Drive Bay Figure 2.
2.1.6 Optional Slim CD-ROM Installation ATM-4023 comes with an optional CD-ROM drawer that is located on the bottom of the chassis. The slim type CD-ROM drawer is integrated with the chassis with slide rails on both sides. The user-friendly CDROM drawer can be released from the chassis by pressing the two latches on both sides of the drawer. Refer the figure 2-7 to find out the location. Figure 2.7: Place for CD-ROM Drawer 2.2 Backplane Please refer figure 2.
2.3 Cooling Fans There are two (2) cooling fans located inside the chassis. The cooling fans are easy to maintain and provide adequate cooling to the system by drawing air into the chassis. Figure 2.9: Cooling Fans 2.4 Installing CPU Cards To install single board computers and other add-on boards: 1. Remove the chassis cover. 2. Take out the hold down clamp 3. Insert the SBC or add-on cards in a suitable location 4. Connect the cables to the CPU Card as instructed 5.
Figure 2.10: Connecting Cables for CPU Card Figure 2.
CHAPTER 3 2 LCD Display Module and Accessories This chapter provides details on the LCD Module and its accessories.
Chapter 3 LCD Display Module and Accessories 3.1 LCD Module Application This product applies computer peripherals, industrial meters, image communication and multi-media. Features • Compatible with VGA-480, VGA-400, VGA-350 and free format • Pixel in stripe configuration • Slim and compact • Display colors: 262,144 colors • Image conversions: Up/down and left/right. • Active area/outline area: 62.3% • Viewing direction: 6 O’clock • Backlight lamps are replaceable 3.1.
Figure 3.
Figure 3.
3.2 LCD Display Module Layout Figure 3.3: LCD Module (Rear) 3.3 Indicator Board Figure 3.
ATM-4023 User Manual 20
A APPENDIX 2 Backplane Layout
Appendix A Backplane Layout A.1 Connectors Figure A.1: PCA-6108P8-0A1: 8-slot Pure PCI backplane, 8 PCI, Rev.
Table A.
A.2 Connector Pin Definitions A.
A.4 Mechanical Dimensions A.5 Note There is support for 3.3 V PCI cards when an ATX power supply is used. No 3.3 V PCI cards are supported if an AT power supply is used.
ATM-4023 User Manual 26