Electrical installation, cable connection, cable cover
DLT-V72 Operating Instructions V2.50 Preliminary 109 / 140
12.5. Closing off unused cable openings
Close off all unused cable openings of the rubber seal using the accompanying blind plugs so that
they are sealed.
Fig. 12.8: Unused cable outlets sealed off with blind plugs
12.6. Attaching the cable cover
NOTICE: Physical damage
Not sealed device due to incorrect attachment of the cables and the cable cover.
The protection class/category of the DLT-V72 is only ensured if the cable cover is properly
installed.
Improper installation can result in liquid penetrating into the DLT-V72 during operation. There is
then a risk of short-circuiting, corrosion and wear.
Place the cable cover in the DLT-V72 housing slot.
Screw the cylinder-head screws loosely into the holes of the cable cover.
Then fully tighten the screws with 3 Nm torque.
Fig. 12.9: Cable cover closed and screwed together