Operating Instructions

Table Of Contents
Integrated power supply, power supply cable
DLT-V72 Operating Instructions V2.50 Preliminary 115 / 140
14. Integrated power supply, power supply cable
DLT-V72 is equipped with a galvanically separated, integrated DC power supply unit.
Power is connected to the back of the unit using a Phoenix Contact plug. There is no power switch.
Fig. 14.1: DC Power supply cable with Phoenix Combicon, 3-pin
WARNING
Electrical shock due to lack of disconnecting device.
The DLT-V72 does not have any externally accessible switching facility, with which the industrial
PC can be quickly disconnected from the power supply in an emergency.
To be able to quickly disconnected the industrial PC from the power supply in emergency
situations:
Install an easily accessible disconnecting device close to the industrial PC, e.g. a suitable
load switch for low voltage.
Make sure that the disconnecting device disconnects all power supply lines.
Power supply
DC power pack
12/24/48 VDC
(wide-range power supply unit)
60 W / 80 W internal
Type DC-16
12/24/48 VDC nominal
Galvanically isolated
Withstands bursts up to 2 kV
Full output power of the 12/24/48 VDC power supply
unit for 20 seconds each:
For 6 V: 40 W
For 9 V: 60 W
Rising in linear fashion between the above
Voltage range 9 to 60 VDC
Bridged power failures Typically 2 ms at 12 V
Typically 10 ms at 24 V
Typically 40 ms at 48 V
Maximum output power 60 W (+10 to +70 °C internal device temperature);
or 80 W (-30 to +10 °C internal device temperature)
Nominal current 8.4 A
Connection to SELV circuit only The SELV circuit is a secondary circuit that is designed
and protected so that its voltages will not exceed a safe
value both when operating correctly or if a single error
occurs.